Data Group
The following describes the historical data group settings specific to the FactoryTalk Historian SE connector.
Group Types
![]() |
For FactoryTalk Historian SE the following group types are available:
Summary Values from Server
This group type retrieves summary calculations directly from the historian. The following calculations are available:
Interpolated
Average
Maximum
Time of Maximum
Minimum
Time of Minimum
Range
Standard Deviation
Total
Count
Raw Average
Start Value
End Value
Delta Value
Percent Good
Percent Bad
Summary Values from XLReporter
This group type retrieves sampled values from the historian and performs calculations on those samples for reporting.
By default, summary values are calculated time weighted, and values are propagated based on the last known value. However, to change this so that summary values are calculated strictly on the data returned check use raw values.
Raw Values
This group retrieves values logged to the historian between the start and end time specified.
Group Settings
Setup Tab (Summary Values for XLReporter)
![]() |
The Retrieval settings define how data is retrieved for the calculations selected for the group. The following settings are available:
Retrieval Mode
This setting defines how data is retrieved from the historian. Both Sampled Values and Raw Values are available where Sampled Values uses the Interpolated calculation.
Rate
The interval (in seconds) that sampled values are retrieved from the historian.
Lead Time
The amount of time (in seconds) to retrieve data before the start time.